Ergonomic Setup for Trans-Radial Procedures Using a Height-Adjustable Trolley in the Angiography Suite.
Kohli Akshay A, Hui Terrence C TC, Schlaphoff Glen G
Trans-radial access (TRA), while experiencing varying global adoption among interventional radiologists, offers potential benefits including reduced access-site bleeding, accelerated patient ambulation, and decreased overall healthcare expenditures compared with trans-femoral access (TFA). However, TRA introduces distinct occupational ergonomic burdens, including asymmetrical arm abduction, working height discrepancies with standard angiographic tables, and inadequate support for long microcatheters and guidewires. These biomechanical constraints heighten operator fatigue and increase the cumulative risk of work-related musculoskeletal disorders. A mobile, height-adjustable trolley-conceptually adapted from ergonomic sit-stand workstations-was integrated into the angiography suite workflow. Arranged parallel to the patient in a Z-shaped spatial configuration, the trolley is linked to the patient's outstretched access arm using an extended sterile drape to establish a stable, continuous sterile working platform. This technical configuration restores neutral operator posture, mitigates lumbar torsion and cervical strain, eliminates sterile field breaches from suspended equipment, and increases the physical working distance from primary scatter radiation sources. Furthermore, the elevated surface facilitates gravity-assisted administration of dense Yttrium-90 microspheres during radioembolization and prevents rotational interference during cone-beam computed tomography acquisitions. The implementation of a height-adjustable trolley provides a simple, cost-effective, and highly adaptable ergonomic solution that optimizes procedural efficiency, sterile field integrity, and radiation safety during trans-radial interventional procedures.