Drug Database
HY

hydroquinone (Tanit)

✓ Approved

Vinas · 小分子 · 小分子

什么是 hydroquinone?

hydroquinone 是一种小分子,由Vinas研发。该药已获批,用于治疗相关适应症。

药物档案

商品名Tanit
公司Vinas
药物类别小分子
状态Approved

治疗适应症

hydroquinone 针对 1 个适应症,涉及 1 个治疗领域。

治疗领域疾病/病症分期
Skin and subcutaneous tissue disordersSkin hyperpigmentation✓ Approved

相关研究文献

PubMedHip international : the journal of clinical and experimental research on hip pathology and therapy2026-11-19

Revisiting the gold standard: why 2-stage revision THA remains relevant for hip PJI: a 10-year experience with excellent infection-free survival.

Noor Syed Shahid SS, Ahmed Nasir N, Wyatt Michael C MC, Khan Sumaiya S et al.

2-stage revision total hip arthroplasty (THA) remains the reference standard for the management of hip periprosthetic joint infection (PJI), despite increasing interest in 1-stage revision. This study reports the 10-year experience of a tertiary referral centre and evaluates infection control, implant survivorship, functional outcomes, and complications following staged revision. A retrospective review of prospectively collected data was performed for patients undergoing staged revision THA for hip PJI between 2014 and 2024. 65 patients met the inclusion criteria and were followed for a mean of 69.3 ± 28.9 months. Functional outcomes were assessed using the modified Harris Hip Score (mHHS). Kaplan-Meier analysis was used to determine implant survivorship, with reoperation, re-revision, recurrent infection, or mortality within 1 year of PJI treatment as survival endpoints. An infection-free survival of 97.0% (63/65) was achieved at final follow-up. Only 2 patients (3.1%) developed recurrent infection, managed with debridement, antibiotics, and implant retention (DAIR) (n = 1) or repeat 2-stage revision (n = 1). Overall, implant survivorship was 87.6% (57/65). The remaining reoperations were attributable to mechanical failures, including aseptic loosening (n = 3, 4.6%), recurrent dislocation (n = 1, 1.5%), and periprosthetic fracture (n = 1, 1.5%). The mean mHHS improved significantly from 26.0 ± 11.8 preoperatively to 68.9 ± 7.4 at final follow-up (mean improvement, 42.9 ± 9.6; p < 0.001). 2-stage revision THA provides excellent infection control, high implant survivorship, and significant functional improvement in patients with hip PJI. These findings reinforce its continued role as a reliable and reproducible treatment strategy, particularly in complex patients managed in real-world clinical practice.

PMID 43053295
阅读全文 →
PubMedPaediatric anaesthesia2026-11-19

Effect of Wrist Extension Angle on Radial and Ulnar Artery Sonoanatomy in Children: A Prospective Ultrasound Study.

Altinbas Sehriban Zeynep SZ, Erkent Fatma Nur Duruk FND, Baytas Volkan V, Ata Tugce T et al.

Ultrasound-guided radial artery cannulation is common in pediatrics but technically challenging. While the ulnar artery is a potential alternative, its sonoanatomy relative to the radial artery is not well defined. This study aimed to compare the sonoanatomic characteristics of the radial and ulnar arteries in children, evaluating how age, weight, and wrist position (0°, 30°, and 45°) influence arterial dimensions and depth to identify the most favorable profile for cannulation. Ultrasound evaluation of the radial and ulnar arteries was performed at 0°, 30°, and 45° wrist extension in 180 anesthetized children aged 0-120 months using custom-made wooden blocks. Arterial dimensions and skin-to-artery distance were evaluated overall and across age (≤ 24 vs. > 24 months) and weight (≤ 12 vs. > 12 kg) subgroups to identify optimal access conditions. Wrist extension angle did not significantly affect anteroposterior diameter (1.4 ± 0.3 mm, p = 0.078), but significantly influenced transverse arterial diameter (1.5-1.6 mm, p = 0.003) and skin-to-artery distance (2.4-2.8 mm at 30°, p < 0.001). The radial artery was widest at 0° (1.6 ± 1.0 mm), while the ulnar artery peaked at 30° (1.6 ± 0.4 mm). Skin-to-artery distance was minimized at 30° for both vessels. In children ≤ 12 kg, radial transverse diameter decreased paradoxically from 0° to 45° (1.6 ± 0.4 to 1.4 ± 0.3 mm, p = 0.013), while the ulnar artery was widest at 30° (1.5 ± 0.3 mm, p = 0.007). In infants ≤ 24 months, wrist angle did not significantly influence radial artery depth (p = 0.631, mean overall depth between 2.5-2.6 mm). A 30° wrist extension angle provides the most favorable sonoanatomic profile for both arteries. Although a larger vessel caliber may potentially facilitate cannulation, its clinical benefit remains uncertain as cannulation outcomes were not assessed. These findings support individualized ultrasound-guided assessment rather than a fixed positioning strategy.

PMID 43052701
阅读全文 →
PubMedNature biomedical engineering2026-11-19

Designer mucin-responsive nanomedicine for enhanced solid tumour penetration and therapy.

Yu Na N, Gong Ningqiang N, Liu Juan J, Zhong Haiping H et al.

While nanomedicines hold great promise for solid tumour therapy, their penetration and access to tumour cells is limited by large glycosylated proteins called mucins that are enriched in the tumour microenvironment. Here we show that mucins induce the disassembly of self-assembled mPEG-polyester micellar nanoparticles into smaller unimers. Leveraging this finding, we designed a mucin-responsive, paclitaxel-conjugated nanomedicine (mrPNM) whose unimers are capable of escaping the mucin-binding barrier. Following intravenous injection, this designer mucin-responsive nanomedicine exhibited markedly deeper penetration than the mucin-nonresponsive nanomedicine and albumin, resulting in 3.9- and 1.5-fold increases in tumour cell delivery, respectively, in a pancreatic mouse tumour model. The mrPNMs also achieved superior tumour growth inhibition compared to both the mucin-nonresponsive nanomedicine and Abraxane, the FDA-approved nanoparticle albumin-bound paclitaxel, in three solid tumour models. The mucin-responsive nanomedicine platform could provide a general strategy for improving the treatment of solid tumours.

PMID 43052497
阅读全文 →
PubMedNature communications2026-11-19

Thermal sculpting of nanoconfined single-atom cavities enables urea electrosynthesis with near-unity selectivity.

Yang Boxuan B, Zeng Yuxin Y, Yin Lifeng L, Dai Yunrong Y et al.

Electrocatalytic urea synthesis from CO2 and NO3- offers a sustainable alternative to energy-intensive industrial methods, yet precise C-N coupling remains hindered by kinetic mismatches between the reduction reactions. Here, we report a strategy leveraging programmable Zn-node gasification to thermally sculpt 1.5-1.8 nm cavities within zeolitic imidazolate frameworks, hosting atomically dispersed Cu-N4 sites. Thermal transformation creates size-matched nanoconfined environments for selective catalysis. An optimal confinement metric descriptor (9.64) is introduced as a predictive parameter, correlating cavity geometry with local electric-field and Cu d-band modulation. This design stabilizes *CO and *NO intermediates, effectively suppressing parasitic reactions and lowering C-N coupling barriers. Consequently, the catalyst delivers a urea yield of 71.32 g gcat-1 h-1 with 98.9% Faradaic efficiency (FE) in gas diffusion cells. Pilot-scale testing demonstrates stable operation over 300 h with an FE of 90%, establishing nanoconfinement as a design principle for competitive-performance urea electrosynthesis.

PMID 43052298
阅读全文 →
PubMedJournal of the American Chemical Society2026-11-19

Split Intein Enables Ultralarge Dual-Phage Display for Drug Discovery.

Shi Leilei L, Wang Weichen W, Wang Dongyao D, Wang Yining Y et al.

Phage display, a powerful ligand discovery technology, is limited by library capacity, with practical diversity typically ∼109 variants. This bottleneck stems from each phage requiring individual host cell propagation, making ultralarge libraries (1012-1014) impractical due to massive cell/culture volume demands. We introduce X-phage, a dual-phage display system using split-intein-mediated ligation to combine two genetically distinct phages into a single functional entity. By randomly combining two small/medium sublibraries (106-107 each), a theoretical maximum diversity of up to 1.5 × 1013 is available in scFv libraries, using standard lab cell/culture volumes. The robustness of X-phage was validated by isolating low-nanomolar ligands against CD33 and TGFβR1; these were further engineered into bispecific engagers and immunomodulators for biotherapeutic applications. This "dual-phage single-phenotype" paradigm decouples library size from bacterial amplification, overcoming traditional capacity limits and enabling high-throughput functional molecule evolution. Thus, X-phage showcases how chemical approaches can advance biotechnology platforms.

PMID 43053366
阅读全文 →
PubMedAdvanced materials (Deerfield Beach, Fla.)2026-11-19

Metallurgical Interface Engineering Constructing In Situ Li3N-Enriched Interphase: A Bulk-Interface Synergy Strategy Toward Practical Silicon Anodes.

Lan Dongrong D, Pan Chuye C, Yang Rui R, Li Chenchen C et al.

Silicon anodes are promising for next-generation lithium-ion batteries but suffer from volume expansion, unstable solid electrolyte interphase (SEI), and sluggish Li+ diffusion. Herein, we report a vacuum-suspension-melted (VSM) bulk multiphase integration and interphase modification strategy to address these challenges. Unlike conventional mechanical mixing, VSM constructs a SiSnM (M = Bi, Ni) composite with metallurgically bonded Si/metal interfaces, forming a conductive network that buffers internal stress via atomic-scale interfacial stress transfer. Simultaneously, a polydopamine-derived nitrogen-doped carbon coating transforms in situ into a Li3N-enriched interphase during cycling, which exhibits high ionic/electronic conductivity, accelerates interfacial charge transfer, and suppresses continuous SEI breakdown. The resulting SiSnM@Li3N anode delivers 87.3% capacity retention after 1000 cycles at 1.5 A g-1 and >1000 mAh g-1 at 15 A g-1, with reliable operation from -30°C to 60°C. Stable cycling at 2.5 mg cm-2 confirms practical relevance. Full cells with Li-rich Mn-based cathodes show stable performance, and 5 Ah-level pouch cells deliver 84.7% capacity retention after 300 cycles at 6 A discharge. This work concurrently tackles ionic, electronic, and mechanical constraints, offering a practical path to high-energy durable Si-based batteries.

PMID 43053316
阅读全文 →

注册免费账户还可查看另外 9996 篇文献

免费注册查看全部文献 →

了解更多hydroquinone